Introduce
Specification (ACY-800: Injection Acrylate)
The driving system: Engine power
Weight: 29 kg
Dimensions (Length x Width x Height): 500mm x 430mm x 600mm
Source: AC 220V 1.1KW
Aggregate ratio: 1: 1
Tank: 10L x 2
Discharge Pressure: Max 300kgf / cm2.G (Recommended at 100kgf / cm2)
Volume of volume: 0.95L ~ 1.9L / min
Special point
Heefeed two components with high efficiency (electric motor).
1: 1 precision error discharge.
Process improvement and adaptation to fast setting products.
The catalyst can be used to adjust the setting time.
Use and move (portable, 29kg) in the field.
Cleaning after use just rinse with water.
Components are easy to replace.
Solution
1) Hole Drilling & Needle Pump Installation
Drill through hole behind the drill concrete connection.
Distance between drill holes 50cm.
Insert the needle into the drill hole.
2) Prepare the injection
Pour component A into A.
Pour component B into comment B.
* A: B ratio is 1: 1.
Pour the catalyst into part A and mix well.
* Basic A (20kg): B (20kg): Catalyst (600g), setting time about 3 minutes.
* Can adjust hardware timing by changing impact quality.
* Due to difference in effect quality, the setting time should be checked before injection.
3) Injections
Cool from low to high.
When the adhesive appears near the crack surface, or high pressure is applied, stop pumping immediately.
Switch to another pump needle and continue pumping.
* If leakage is high, increase the amount of catalyst to shorten setting time.
4) Finish
Cut and remove metal pump settings.
Surface grinding with grinder.
Finish with finishing materials.
User manual
(1) Drill holes – check for cracks and holes in the back of structural concrete and use air compressor to blow holes clean.
(2) Needle insertion – insert the needle into the hole and tie the needle with a T wrench.
(3) Pour component A into flask A
(4) Pour the catalyst and component A and evenly with a chopstick.
(4) Pour component B into comment B
(5) Check the setting time (a): pour each part into paper cup.
(6) Set time test (b): combine in 1: 1 ratio.
(7) Check setting time (c): if the setting time is long, increase the quality of the impact to shorten the setting time.
(8) Loosen by piston.
(9) Connect the gun to the hose.
(10) Connect the gun to the pump needle already installed.
(11) Turn on the switches for the treadmill and pump acrylic into the holes.
(12) After finishing the pump, please discard the metal pump.
(13) Clean the crack / hole area and cover with surface material.
Copy topology
1) The last basement
2) Tran P.C / R.C
3) Walls
Safe
Fully equipped with labor protection such as frames, glasses, clothes,….
In the event that the library gets into the skin, wash immediately with soap and flush with plenty of water.
In case of contact with eyes, wash immediately with plenty of water and seek immediate medical attention.
It operates on electricity so it is necessary to comply with regulations on electrical safety and avoid fire and explosion.
Note
Because it is motor-driven, proper procedure should be used to prolong the service life of the pump.
It is most important to maintain correct usage times. Time to use each time is 40 minutes. Therefore, after using for 40 minutes, let the machine rest for 5 minutes for the machine to cool down.
Stripping water for parts (such as motors, wires, switches, etc.)
Don’t miss & improve the product.
Do not use when the product is damaged or damaged.
Do not collide with other objects or drop them.
Only use 220V power source.
If there is an unknown quality in the product, it may be abandoned.
license
This product is protected by intellectual property rights. Therefore, counterfeiting and counterfeiting products are strictly prohibited by law. If someone falls under the jurisdiction, we will hold the involved party to civil / formal liability and will claim damages. In addition, the illegal copying of all or part of technical documentation relating to the product for sale or distribution is prohibited.